Phase III ESAs are designed to mitigate environmental concerns identified in the Phase I ESA and subsequent Phase II subsurface investigation. RRC develops risk-based solutions to address actual or potential contamination. Based upon the anticipated future use of a site, alternative site-specific cleanup solutions can be designed.  The corrective action could involve physical removal or in situ treatment of the contamination as well as a risk-assessment to demonstrate that the contamination does not pose a threat to health and safety and can remain undisturbed.

Risk-based approaches can also be used to allocate funds and resources in prioritizing and addressing risks based on the magnitude of the hazard. Commercial property acquisitions can be structured to isolate and treat separately, the higher risk, contaminated portions of a property.

Incorporating the needs of various interest groups may also be identified as a goal. Sites may be entered into state voluntary cleanup programs such as the Illinois EPA's  Site Remediation Program (SRP) or  Iowa DNR’s Land Recycling Program (LRP). RRC has experience in working with such regulatory programs employing flexible, risk-based cleanup plans to achieve a formal "No Further Action" classification for the site.

 

Exposure Route-Specific Values for Soils

Soil Component of the Groundwater Ingestion Exposure Route

Values

 

CAS No.

Chemical Name

Ingestion

(mg/kg)

Inhalation

(mg/kg)

Class I

(mg/kg)

Class II

(mg/kg)

ADL

(mg/kg)

79-00-5

1,1,2-Trichloroethane

310b

1,800d

0.02

0.3

*

79-01-6

Trichloroethylene

58e

5e

0.06

0.3

*

108-05-4

Vinyl acetate

78,000b

1,000b

170b

170

*

75-01-4

Vinyl chloride

0.46e

0.28e

0.01f

0.07

*

Media

Exposure Pathway

Receptor

Group 1

Group 2: TEH

Benzene

Toluene

Ethylbenzene

Xylenes

Diesel*

Waste Oil

Groundwater (ug/L)

Groundwater Ingestion

actual

5

1,000

700

10,000

1,200

400

potential

290

7,300

3,700

73,000

75,000

40,000

Groundwater Vapor to Enclosed Space

all

1,540

20,190

46,000

NA

2,200,000

NA

Groundwater to Plastic Water Line

all

290

7,300

3,700

73,000

75,000

40,000

Surface Water

all

290

1,000

3,700

73,000

75,000

40,000

Soil (mg/kg)

Soil Leaching to Groundwater

all

0.54

42

15

NA

3,800

NA

Soil Vapor to Enclosed Space

all

1.16

48

79

NA

47,500

NA

Soil to Plastic Water Line

all

1.8

120

43

NA

10,500

NA